How does Starfield's
digital lighting control system
compare to other systems? |
|
|
Switched |
0-10v |
Standard
DALI
|
Lutron
Eco-System
|
Starfield
|
|
Works without powerpacks or
interfaces to sensors
(1)(4)
|
NO |
NO |
NO |
YES |
YES
|
|
Scalable to any project size
(2)
|
YES |
NO |
NO |
YES |
YES |
|
Ballast replacement without
reprogramming
(3)
|
YES |
YES |
NO |
YES |
YES |
|
Easily integrates with
daylighting |
NO |
NO |
NO |
YES |
YES |
|
Zones are programmed, not wired |
NO |
NO |
YES |
YES |
YES |
|
Controls are reconfigurable or adjustable
without going above a ceiling |
NO |
NO |
NO |
YES |
YES |
|
Communication wiring can be
Class 1 or Class 2 |
NO |
NO |
YES |
YES |
YES |
|
Class 2 sensor and wall station
wiring (4) |
NO |
NO |
NO |
YES |
YES |
|
Out-of-box functionality
for
daylighting, occupancy sensing
and manual control |
NO |
NO |
NO |
YES |
YES |
|
Non-proprietary ballasts
(5) |
YES |
YES |
YES |
NO |
YES |
|
Architectural dimming
(6) |
NO |
NO |
YES |
NO |
YES |
Comparison
Chart Notes
(1) Sensor Connections
- Ecosystem sensors and controls
connect to the Ecosystem ballast.
Starfield sensors connect to the
Starfield controller and the controller
connects directly to the DALI bus.
(2) Scalability -
The Starfield system uses standard
TCP/IP protocol and network architecture
that supports unlimited local and global
scalability without the use of lighting
control panels required by EcoSystem.
(3) Ballast
Replacement - Both EcoSystem and
Starfield maintain
a database of ballast settings which are
automatically downloaded when a single
ballast is replaced and manually
downloaded if multiple ballasts are
replaced.
(4) Class 2 Wiring
- EcoSystem sensors and controls connect
to the EcoSystem ballast with Class 2
cable. This cable is connected to
the EcoSystem ballast so it must be run
into the light
fixture and separated from
power wire in accordance with NEC
Article 725 requirements. Starfield
controllers are Class 2 devices which
are UL Listed to connect to the DALI bus
with either Class 1 or Class 2 cable
eliminating the need to run sensor and
control wiring into the light fixture.
(5) Non-proprietary
Ballasts - Starfield uses standard DALI
compliant ballasts available in a wide range of
models from multiple manufacturers.
EcoSystem uses proprietary ballasts
available only from Lutron in a limited
range of models.
(6)
Architectural Dimming -
Standard DALI ballasts used by Starfield
dim to 1% (linear) and 3% (CFL) allowing
a single system to be used in both
offices and
conference rooms. Architectural control systems like the
Lutron GRAFIK Eye use 1% dimming
not available from EcoSystem
ballasts, which only dim to 10%.
Need a spec?
Send an email to get a copy of
Starfield's model specification to use
for your project. Please include your
name, company, email address and phone
number. Or, call Greg Dreith at
303.427.1661 for immediate application
assistance.
|